Leave Your Message
Products Categories
Featured Products

Hot Sale Mit su bishi PLC Controller FX3U-485-BD Communication Module FX3U485BD

PLC, FX3U 485 Interface module, 1:n Multidrop, network expansion until 50 m

 

We're one of the most professional One-stop suppliers in China. Our main products including servo motor, planetary gearbox, inverter and PLC, HMI. Brands including Panasonic, Mitsubishi,  Delta, XINJE,Scheider, Siemens , Omron and etc.;  Shipping time: Within 3-5 working days after getting the payment.  Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on

    products1bmdFX3U-485-BD1xy0
    Rich features and flexible system configuration in a compact size.
    The MELSEC-F series PLC incorporates power supply, CPU, and I/Os into a single compact unit.
    Meets the needs of a variety of user applications with options for I/O, analog, positioning, and open network expansion.

    Specifications

    High functionality model (FX3U/FX3UC)
    Faster, friendlier. Realize high expand ability and high functionality.
    From high speed control to network support and even logging is possible.
    FX3 series flagship model FX3U and connector type FX3UC: 2 models are available.
    Standard model (FX3G/FX3GC)
    More advanced control for automation and networking.
    Equipped with functions required for standard controls, and fit for various purposes.
    Compact sized with the same performance, FX3GC is also available.
    Basic model (FX3S)
    Easy introduction to machine automation.
    Simple functions and economical price in one package.
    A basic micro PLC with expand ability for analog and communication functions.
    FX series I/O extension devices are divided into "extension blocks" and "powered extension units".
    "Powered extension units" have built-in power supply and also extend I/O at the same time."Extension blocks" adjust the I/O of the main unit or powered extension units in 8 point or 16 point units.
    Connecting extension devices Some extension devices must be mounted on the main unit before the unit is installed in the enclosure. • Mount the expansion board and special adapters on the main unit before installing it in the enclosure. • Mount the input/output powered extension units/blocks and the special function units/blocks in the enclosure after installing the main unit in the enclosure. • The memory cassette and the display module can be fitted to the main unit after it is installed. • The battery can be replaced with a new one in the state where the main unit is in the enclosure
    FX3U-485-BD2720FX3U-485-BD3m09FX3U-485-BD4kppFX3U-485-BD5hlmFX3U-485-BD64ndFX3U-485-BD7kbi
    *1. These power consumption values are maximum values which apply to the main unit's 24V DC service power supply when there are input/output extension blocks and special function units/blocks. → For input/output powered extension units/blocks power consumption information, refer to Section 15.2. *2. When input/output extension blocks are connected, 24V DC service power is consumed by the blocks, and the power to be consumed by the main unit is reduced. → For details on the 24V DC service power supply, refer to Section 6.5. *3. 24V DC service power is not provided to FX3U-32MR/UA1 and FX3U-64MR/UA1. *4. The power supply is not for external use. The current capacity specified above is for the input/output extension blocks, special function blocks, special adapters and expansion boards. *5. 250V 5A is specified for the power fuse of FX3U-32MR/UA1.
    FX3U-485-BD83nbFX3U-485-BD9drl

    Description

    High speed counter block/adapter
    Model (Number of channels) Type Highest response frequency Hardware comparison output function 2-phase counter edge count function Applicable FX PLC
    FX3S FX3G FX3U FX3GC FX3UC  
    FX2N-1HC (1ch) 1-phase 1-count Max. 50 kHz - × × ○ Max. 8 units × *2*3 ○ Max. 8 units
    1-phase 2-count Max. 50 kHz
    2-phase 2-count 1 edge count: Max. 50 kHz 2 edge count: Max. 25 kHz 4 edge count: Max. 12.5 kHz
    FX3U-2HC (2ch) 1-phase 1-count Max. 200 kHz - × × ○ Max. 8 units × *2 ○ Max. 4 units
    1-phase 2-count Max. 200 kHz
    2-phase 2-count 1 edge count: Max. 200 kHz 2 edge count: Max. 100 kHz 4 edge count: Max. 50 kHz
    FX2NC-1HC (1ch) 1-phase 1-count Max. 50 kHz - × × × × *3 ○ Max. 8 units
    1-phase 2-count Max. 50 kHz
    2-phase 2-count 1 edge count: Max. 50 kHz 2 edge count: Max. 25 kHz 4 edge count: Max. 12.5 kHz
    FX3U-4HSX-ADP (4ch) 1-phase 1-count Max. 200 kHz × × × *1 ○ Max. 2 units × ×
    1-phase 2-count Max. 200 kHz
    2-phase 2-count 1 edge count: Max. 100 kHz 4 edge count: Max. 100 kHz
    *1: When used together with analog or communication adapters, function expansion board is required.
    *2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
    *3: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
    Power Supply (V) 100-240
    Current Type AC
    Program Memory 64K STEPS
    Program Memory Unit RAM
    Integrated Digital Inputs 16
    Integrated Digital Outputs 16
    Output Type RELAY
    Local I/O Points 256
    Local + Remote I/O Points 384
    Power Consumption (W) 35
    Dimensions (W x H x D) in mm 150*90*86  (0.65kg)
    Protection Class IP10

    Applications

    • Transmitter output suitable for ON / OFF control devices Required 1A ~ 2A
    • Use Widely used in controllers of industrial systems from simple to complex
    • Widely used in textiles, plastic packaging, food ...
    • Automated systems in medicine, electronics, mechanics, machinery ...
    • Multi-sector applications: packaging, waste treatment, pumps, transmitters
    products (3)w9o

    Leave Your Message